INSTALLATION INSTRUCTIONS MRKP1E Keypad controller EU and UK Standard

Page 2

9 MRKP1E – REAR CONNECTORS Figure 2.3: Rear connector board of MRKP1E Keypad ITEM DESCRIPTION 1 Expansion RJ-45 Port 2 Controller RJ-45 Port

Page 3

13 Internal IR Receiver The internal IR receiver is located beneath the center of the keypad’s face plate. The internal IR receiver receives IR comm

Page 4 - 6. Specifications

11 Note: Do not mount the MRKP1E in the same electrical back- box as high voltage devices such as electrical outlets or switches. Figure 2.5: MRK

Page 5 - 1.0 Introduction

1 Safety Information Read Information — All the safety and operating information should be read before the appliance is operated. Follow Informatio

Page 6

21 2 Safety Check — Upon completion of any service or repairs to this audio product, ask the service technician to perform safety checks to determi

Page 7

3 • Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. •

Page 8

19 5. Troubleshooting Symptom Possible Cause Solution MRKP1E does not power up 1. RJ-45 plug crimped incorrectly; or wiring pin-out of

Page 9 - 4. MRKP1E Main Setup Menu

5 Defining Terms Zone A Zone is defined as an area of the house that has separate source selection capabilities from all other areas of the house. Ty

Page 10 - EXPANSION CONTROLLER

17 Fig. 4.1 Main Setup Menu Diagram (continued on next page) (MRC88m/MRAUDIO8X8m require Firmware Ver. 2.03 or later to work with the MRKP1E) co

Page 11

7 Pre-Wiring CAT-5 Wiring between MRC88m and MRKP1E The MRC88m and all associated components are wired using CAT-5 terminated to the T568A or T568B

Page 12 - 3. Connections

15 SETUP button X button 4. MRKP1E Main Setup Menu To access the Main Setup Menu, 1. Press and hold down the “X” key for at least 3 seconds. 2.